Technical Parameters Of Hot Air Circulation Drying

Jul 12, 2026 Leave a message

Thermal efficiency is approximately 70%. Temperature range is from room temperature to 350℃, with high-temperature models reaching 500℃.

1. Heating sources include steam, electricity, far-infrared, and dual-purpose electric and steam.

2. Operating temperature: Steam heating 50-140℃, maximum 150℃; Electric and far-infrared heating 50-350℃.

3. Optional automatic control system or computer control system.

4. Common steam pressure range is 0.02-0.8Mpa (0.2-8kgf/cm²).

5. Electric heating power is calculated at 15kW for type I, with actual power consumption of approximately 5-8kW/h.

6. Special requirements must be specified when ordering.

7. Operating temperatures above 140℃ or below 60℃ must be specified when ordering.

Non-standard customization is supported, including customizable dimensions, temperature ranges, and structural types.

8. The drying carts and trays配套 with this equipment are of uniform size and interchangeable.

9. The drying tray dimensions are 640×460×45mm.

The temperature control system can use a digital display intelligent instrument with PID control. Components such as the cabinet, drying cart, and drying trays can be made of carbon steel or stainless steel, depending on requirements.